{"id":6368,"date":"2025-07-05T19:41:21","date_gmt":"2025-07-05T10:41:21","guid":{"rendered":"https:\/\/tuat-chemphys.net\/?p=6368"},"modified":"2025-07-05T19:41:21","modified_gmt":"2025-07-05T10:41:21","slug":"%e3%82%88%e3%82%8a%e5%ae%89%e5%85%a8%e3%81%aa%e8%96%ac%e3%81%a5%e3%81%8f%e3%82%8a%e3%81%ae%e3%81%9f%e3%82%81%e3%81%ae%e3%82%b9%e3%83%9e%e3%83%bc%e3%83%88%e3%81%aa%e7%9b%a3%e8%a6%96%e6%8a%80%e8%a1%93-s","status":"publish","type":"post","link":"https:\/\/tuat-chemphys.net\/?p=6368","title":{"rendered":"\u3088\u308a\u5b89\u5168\u306a\u85ac\u3065\u304f\u308a\u306e\u305f\u3081\u306e\u30b9\u30de\u30fc\u30c8\u306a\u76e3\u8996\u6280\u8853 Smarter Monitoring for Safer Medicine Production"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/doi.org\/10.1248\/cpb.c24-00652\">https:\/\/doi.org\/10.1248\/cpb.c24-00652<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u85ac\u3092\u4f5c\u308b\u5de5\u5834\u3067\u4f7f\u308f\u308c\u308b\u300c\u9023\u7d9a\u88fd\u9020\u300d\u3068\u3044\u3046\u65b9\u6cd5\u306b\u304a\u3044\u3066\u3001\u6a5f\u68b0\u306e\u7570\u5e38\u3084\u539f\u6599\u306e\u5909\u5316\u3092\u898b\u3064\u3051\u308b\u305f\u3081\u306e\u65b0\u3057\u3044\u65b9\u6cd5\u3092\u63d0\u6848\u3057\u3066\u3044\u307e\u3059\u3002\u4f7f\u308f\u308c\u3066\u3044\u308b\u306e\u306f\u300c\u591a\u5909\u91cf\u7d71\u8a08\u7684\u30d7\u30ed\u30bb\u30b9\u7ba1\u7406\uff08MSPC\uff09\u300d\u3068\u3044\u3046\u6280\u8853\u3067\u3001\u305f\u304f\u3055\u3093\u306e\u30bb\u30f3\u30b5\u30fc\u304b\u3089\u306e\u30c7\u30fc\u30bf\u3092\u307e\u3068\u3081\u3066\u5206\u6790\u3059\u308b\u3053\u3068\u3067\u3001\u7570\u5e38\u3092\u898b\u3064\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u3082\u3001\u3053\u308c\u307e\u3067\u306e\u65b9\u6cd5\u3067\u306f\u300c\u9593\u9055\u3063\u3066\u7570\u5e38\u3068\u5224\u65ad\u3057\u3066\u3057\u307e\u3046\u300d\u3053\u3068\u304c\u591a\u304f\u3042\u308a\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u30c7\u30fc\u30bf\u306e\u300c\u6a19\u6e96\u5316\uff08\u30b9\u30b1\u30fc\u30ea\u30f3\u30b0\uff09\u300d\u306e\u65b9\u6cd5\u3092\u5de5\u592b\u3059\u308b\u3053\u3068\u3067\u3001\u7570\u5e38\u3092\u6b63\u3057\u304f\u898b\u3064\u3051\u308b\u7cbe\u5ea6\u3092\u9ad8\u3081\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u306a\u305c\u3053\u306e\u7814\u7a76\u304c\u5927\u5207\uff1f<\/strong><br>\u85ac\u306e\u88fd\u9020\u3067\u306f\u3001\u54c1\u8cea\u3092\u4fdd\u3064\u3053\u3068\u304c\u3068\u3066\u3082\u91cd\u8981\u3067\u3059\u3002\u7570\u5e38\u3092\u65e9\u304f\u898b\u3064\u3051\u308b\u3053\u3068\u3067\u3001\u5b89\u5168\u3067\u9ad8\u54c1\u8cea\u306a\u85ac\u3092\u5b89\u5b9a\u3057\u3066\u4f5c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30c7\u30fc\u30bf\u306e\u6271\u3044\u65b9\u3072\u3068\u3064\u3067\u7d50\u679c\u304c\u5927\u304d\u304f\u5909\u308f\u308b\u3053\u3068\u3092\u77e5\u308b\u3068\u3001\u79d1\u5b66\u3084\u5de5\u5b66\u306e\u9762\u767d\u3055\u3092\u611f\u3058\u3089\u308c\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This study focuses on improving how we detect problems in pharmaceutical continuous manufacturing\u2014a modern method for making medicines. The researchers used a technique called Multivariate Statistical Process Control (MSPC), which analyzes data from many sensors to spot unusual behavior.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, previous methods often gave false alarms. This study found that by adjusting how the data is scaled (standardized), the system can more accurately detect real issues\u2014like changes in machine settings or raw materials\u2014without being confused by small, harmless fluctuations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Why is this research important?<\/strong><br>In medicine production, ensuring consistent quality is critical. Detecting anomalies early helps prevent defective products and keeps patients safe. This shows how smart data handling can make a big difference in real-world technology!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"997\" height=\"743\" data-attachment-id=\"6370\" data-permalink=\"https:\/\/tuat-chemphys.net\/?attachment_id=6370\" data-orig-file=\"https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5.png\" data-orig-size=\"997,743\" data-comments-opened=\"0\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"image\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5.png\" src=\"https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5.png\" alt=\"\" class=\"wp-image-6370\" srcset=\"https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5.png 997w, https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5-300x224.png 300w, https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5-768x572.png 768w, https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-5-360x268.png 360w\" sizes=\"auto, (max-width: 997px) 100vw, 997px\" \/><figcaption class=\"wp-element-caption\">Process Flow of Continuous Wet Granulation Process \u9023\u7d9a\u6e7f\u5f0f\u9020\u7c92\u30d7\u30ed\u30bb\u30b9\u306e\u30d7\u30ed\u30bb\u30b9\u30d5\u30ed\u30fc<\/figcaption><\/figure>\n\n\n\n<p class=\"has-pale-ocean-gradient-background has-background wp-block-paragraph\">Journal: Chemical and Pharmaceutical Bulletin<br>Volume 73 (2025) Issue 3\/Regular Article <a href=\"https:\/\/doi.org\/10.1248\/cpb.c24-00652\">https:\/\/doi.org\/10.1248\/cpb.c24-00652<\/a><br><strong>Highly Precise Anomaly Detection Using Multivariate Statistical Process Control with Appropriate Scaling of Input Variables in Pharmaceutical Continuous Manufacturing<\/strong><br>Takuya Oishi, Takuya Nagato, Chikara Tsujikawa, Takuya Minamiguchi, Sanghong Kim<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This study proposes improved scaling methods for Multivariate Statistical Process Control (MSPC) to enhance anomaly detection in pharmaceutical continuous manufacturing. By applying these methods to wet granulation and fluidized bed drying processes, the researchers demonstrated that appropriate scaling\u2014based on combined datasets or domain knowledge\u2014significantly reduces false positives and improves detection accuracy. The MSPC models successfully identified both equipment-related and raw-material-related anomalies, offering a practical framework for real-time monitoring and quality assurance in pharmaceutical production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u88fd\u85ac\u306e\u9023\u7d9a\u88fd\u9020\u306b\u304a\u3051\u308b\u7570\u5e38\u691c\u51fa\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u306b\u3001\u591a\u5909\u91cf\u7d71\u8a08\u7684\u30d7\u30ed\u30bb\u30b9\u7ba1\u7406\uff08MSPC\uff09\u306e\u30b9\u30b1\u30fc\u30ea\u30f3\u30b0\u624b\u6cd5\u3092\u6539\u826f\u3057\u307e\u3057\u305f\u3002\u63d0\u6848\u624b\u6cd5\u3092\u6e7f\u5f0f\u9020\u7c92\u304a\u3088\u3073\u6d41\u52d5\u5c64\u4e7e\u71e5\u30d7\u30ed\u30bb\u30b9\u306b\u9069\u7528\u3057\u3001\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u30c7\u30fc\u30bf\u3068\u975e\u6b63\u5e38\u30c7\u30fc\u30bf\u306e\u7d44\u307f\u5408\u308f\u305b\u3001\u307e\u305f\u306f\u30d7\u30ed\u30bb\u30b9\u306b\u95a2\u3059\u308b\u5c02\u9580\u77e5\u8b58\u306b\u57fa\u3065\u304f\u30b9\u30b1\u30fc\u30ea\u30f3\u30b0\u306b\u3088\u308a\u3001\u8aa4\u691c\u51fa\u7387\u306e\u4f4e\u6e1b\u3068\u691c\u51fa\u7cbe\u5ea6\u306e\u5411\u4e0a\u3092\u5b9f\u8a3c\u3057\u307e\u3057\u305f\u3002MSPC\u30e2\u30c7\u30eb\u306f\u3001\u88c5\u7f6e\u306e\u7570\u5e38\u3060\u3051\u3067\u306a\u304f\u539f\u6599\u306e\u5909\u5316\u3082\u691c\u51fa\u53ef\u80fd\u3067\u3042\u308a\u3001\u88fd\u85ac\u88fd\u9020\u306b\u304a\u3051\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u76e3\u8996\u3068\u54c1\u8cea\u4fdd\u8a3c\u306e\u5b9f\u7528\u7684\u306a\u67a0\u7d44\u307f\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7570\u5e38\u3092\u65e9\u304f\u898b\u3064\u3051\u308b\u3053\u3068\u3067\u3001\u5b89\u5168\u3067\u9ad8\u54c1\u8cea\u306a\u85ac\u3092\u5b89\u5b9a\u3057\u3066\u4f5c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 Detecting anomalies early helps prevent defective products and keeps patients safe.<\/p>\n","protected":false},"author":1,"featured_media":6369,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"advanced_seo_description":"","jetpack_seo_html_title":"","jetpack_seo_noindex":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[9],"tags":[16],"class_list":["post-6368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research","tag-measurement-devices"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/tuat-chemphys.net\/wp-content\/uploads\/2025\/07\/image-4.png","jetpack_sharing_enabled":true,"jetpack-related-posts":[{"id":7245,"url":"https:\/\/tuat-chemphys.net\/?p=7245","url_meta":{"origin":6368,"position":0},"title":"[PhD Seminar] Controlling Medicine Crystals with Fluid Dynamics: The Power of Taylor-Couette Vortex\u3010\u535a\u58eb\u8ad6\u6587\u516c\u8074\u4f1a\u3011\u6d41\u4f53\u529b\u5b66\u3067\u85ac\u3092\u5275\u308b\uff1a\u30c6\u30a4\u30e9\u30fc\u30fb\u30af\u30a8\u30c3\u30c8\u6d41\u308c\u306b\u3088\u308b\u7d50\u6676\u306e\u5236\u5fa1 (2\/9 10:30)","author":"unet","date":"2026-02","format":false,"excerpt":"This research explores how specialized \"vortex\" flows can be used to create high-quality medicinal crystals. \u533b\u85ac\u54c1\u88fd\u9020\u306e\u65b0\u3057\u3044\u624b\u6cd5\u306b\u95a2\u3059\u308b\u535a\u58eb\u8ad6\u6587\u516c\u8074\u4f1a\u3092\u958b\u50ac\u3057\u307e\u3059\u3002\u672c\u7814\u7a76\u306f\u3001\u7279\u6b8a\u306a\u300c\u6e26\u300d\u306e\u6d41\u308c\u3092\u5229\u7528\u3057\u3066\u3001\u9ad8\u54c1\u8cea\u306a\u85ac\u306e\u7d50\u6676\u3092\u4f5c\u308a\u51fa\u3059\u6280\u8853\u306b\u3064\u3044\u3066\u63a2\u6c42\u3057\u3066\u3044\u307e\u3059\u3002","rel":"","context":"In &quot;Doctoral Thesis \u535a\u58eb\u8ad6\u6587&quot;","block_context":{"text":"Doctoral Thesis \u535a\u58eb\u8ad6\u6587","link":"https:\/\/tuat-chemphys.net\/?cat=22"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/02\/image-2.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/02\/image-2.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/02\/image-2.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":6830,"url":"https:\/\/tuat-chemphys.net\/?p=6830","url_meta":{"origin":6368,"position":1},"title":"Alumni \u6d3b\u8e8d\u3059\u308b\u5352\u696d\u751f","author":"unet","date":"2022-12","format":false,"excerpt":"\u6771\u5317\u5927\u5b66\u591a\u5143\u7269\u8cea\u79d1\u5b66\u7814\u7a76\u6240\u30fb\u52a9\u6559\u3001JST\u5275\u767a\u7814\u7a76\u8005\u3002Assistant Professor at Tohoku University. JST FOREST Researcher","rel":"","context":"In &quot;Alumni.\u5352\u696d\u751f&quot;","block_context":{"text":"Alumni.\u5352\u696d\u751f","link":"https:\/\/tuat-chemphys.net\/?cat=24"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.30.59.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":7779,"url":"https:\/\/tuat-chemphys.net\/?p=7779","url_meta":{"origin":6368,"position":2},"title":"\u5f53\u5b66\u79d1\u306e\u300c\u91cf\u5b50\u6280\u8853\u300dQuantum technology research at our department","author":"unet","date":"2026-04","format":false,"excerpt":"\u91cf\u5b50\u306e\u4e16\u754c\u306f\u3001\u7269\u7406\u3084\u5316\u5b66\u306e\u300c\u5f53\u305f\u308a\u524d\u300d\u304c\u901a\u3058\u306a\u3044\u4e0d\u601d\u8b70\u306a\u5834\u6240 The \"Quantum-Tech\" tag, highlighting our lineup of researchers pushing the boundaries of what is scientifically possible.","rel":"","context":"In &quot;Lab. Intro \u7814\u7a76\u5ba4\u7d39\u4ecb&quot;","block_context":{"text":"Lab. Intro \u7814\u7a76\u5ba4\u7d39\u4ecb","link":"https:\/\/tuat-chemphys.net\/?cat=6"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/04\/Gemini_Generated_Image_tnsv0ctnsv0ctnsv.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":6824,"url":"https:\/\/tuat-chemphys.net\/?p=6824","url_meta":{"origin":6368,"position":3},"title":"Alumni \u6d3b\u8e8d\u3059\u308b\u5352\u696d\u751f","author":"unet","date":"2017-10","format":false,"excerpt":"\u5927\u5b66\u9662\u5de5\u5b66\u7814\u7a76\u79d1\u3092\u4fee\u4e86\u5f8c\u3001\u65e5\u7d4cBP\u793e\u306b\u5c31\u8077\u3057\u305f\u5c71\u6839\u3055\u3093\u3002The Editor-in-Chief of Nikkei Energy Next (2016)","rel":"","context":"In &quot;Alumni.\u5352\u696d\u751f&quot;","block_context":{"text":"Alumni.\u5352\u696d\u751f","link":"https:\/\/tuat-chemphys.net\/?cat=24"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/09\/%E3%82%B9%E3%82%AF%E3%83%AA%E3%83%BC%E3%83%B3%E3%82%B7%E3%83%A7%E3%83%83%E3%83%88-2025-09-27-8.23.54.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":7968,"url":"https:\/\/tuat-chemphys.net\/?p=7968","url_meta":{"origin":6368,"position":4},"title":"\u539f\u5b50\u30b9\u30d4\u30f3\u3067\u5149\u306e\u5468\u6ce2\u6570\u3092\u5909\u3048\u308b\u65b0\u3057\u3044\u65b9\u6cd5 Controlling Light Frequency Using Atomic Spin Rotation \u65e5\u672c\u7269\u7406\u5b66\u4f1a\u300c\u5b66\u751f\u512a\u79c0\u767a\u8868\u8cde\u300dOutstanding Presentation Award, Physical Society of Japan","author":"unet","date":"2026-06","format":false,"excerpt":"This approach enables larger frequency shifts and may lead to new ways of controlling light.\u305d\u306e\u7d50\u679c\u3001\u5f93\u6765\u3088\u308a\u3082\u5927\u304d\u306a\u5468\u6ce2\u6570\u5909\u5316\u304c\u5f97\u3089\u308c\u3001\u5149\u306e\u65b0\u3057\u3044\u5236\u5fa1\u6280\u8853\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002","rel":"","context":"In &quot;Awards&quot;","block_context":{"text":"Awards","link":"https:\/\/tuat-chemphys.net\/?cat=3"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/06\/image.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/06\/image.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2026\/06\/image.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":6956,"url":"https:\/\/tuat-chemphys.net\/?p=6956","url_meta":{"origin":6368,"position":5},"title":"Surface Plasmon Resonance sensors for highly selective detection of carboxylic acids \u2014 SPR\u30bb\u30f3\u30b5\u30fc\uff1a\u9162\u9178\u306a\u3069\u306e\u30ab\u30eb\u30dc\u30ad\u30b7\u30eb\u57fa\u3092\u6301\u3064\u5206\u5b50\u306e\u9ad8\u9078\u629e\u7684\u691c\u51fa","author":"unet","date":"2025-11","format":false,"excerpt":"\u672c\u7814\u7a76\u306f\u3001\u8868\u9762\u30d7\u30e9\u30ba\u30e2\u30f3\u5171\u9cf4\uff08SPR\uff09\u30bb\u30f3\u30b5\u30fc\u306b\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30a4\u30df\u30f3\uff08PEI\uff09\u3092\u88c5\u98fe\u3059\u308b\u3053\u3068\u3067\u3001\u9162\u9178\u306a\u3069\u306e\u30ab\u30eb\u30dc\u30ad\u30b7\u30eb\u57fa\u3092\u6301\u3064\u5206\u5b50\u3092\u9ad8\u9078\u629e\u7684\u306b\u691c\u51fa\u3067\u304d\u308b\u3053\u3068\u3092\u793a\u3057\u307e\u3057\u305f\u3002This work demonstrates that decorating SPR sensors with PEI enables highly selective detection of carboxylic acid like acetic acid.","rel":"","context":"In &quot;Research Topics&quot;","block_context":{"text":"Research Topics","link":"https:\/\/tuat-chemphys.net\/?cat=9"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/tuat-chemphys.net\/wp-content\/uploads\/2025\/11\/image-4.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"jetpack_shortlink":"https:\/\/wp.me\/pa3J4g-1EI","jetpack_likes_enabled":true,"_links":{"self":[{"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/posts\/6368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6368"}],"version-history":[{"count":2,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/posts\/6368\/revisions"}],"predecessor-version":[{"id":6372,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/posts\/6368\/revisions\/6372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=\/wp\/v2\/media\/6369"}],"wp:attachment":[{"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=6368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tuat-chemphys.net\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=6368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}